7-26
System Control:
Quick-Key Parameter Default Range
11
22
0606
Bell Squawk
Y
ES
YES/NO
Y
ES: The following signals are emitted by the external sounder to acknowledge
whether you have successfully activated/deactivated the system:
One tone means that the system is activated.
Two tones mean that the system is deactivated.
Four tones mean that the system is deactivated following an alarm.
NO: No confirmation is made by the sounder.
11
22
0707
Bell 30/10 NO
YES/NO
Y
ES: The sounders interrupt the alarm tone for 10 seconds every 30 seconds.
NO: The sounders emit continuous alarm tones without interruption.
11
22
0808
Phone Cut Alarm NO
YES/NO
Y
ES: Monitors the telephone line and activates the sounder if the telephone line is
cut for the period defined under Phone Line Cut Delay Time. (See also
Phone Line Cut Delay time on page 7-24.)
NO: The telephone line is not monitored and there is no alarm.
11
22
0909
3 Minute Bypass NO
YES/NO
Y
ES: After the system has been supplied with power, zones are automatically
omitted for 3 minutes to give detectors a chance to stabilise.
NO: The zones are monitored as soon as the system is activated.
11
22
1010
Audible Panic NO
YES/NO
Y
ES: In the event of a panic alarm, an audible alarm is issued.
NO: In the event of a panic alarm, it is transmitted by telephone. The system does not
trigger any audible alarms locally.
11
22
1111
Buzzer Æ Bell NO
YES/NO
Y
ES: If the system is activated internally and an alarm is triggered, an alarm is
sounded for 15 seconds on the operating panels before the system activates
the external sounders and the alarm is transmitted by telephone.
NO: If the system is activated internally and an alarm is triggered, the external
sounders and the telephone line are activated immediately.
11
22
1212
Fire Temporal Pattern
Y
ES
YES/NO
Y
ES: The fire signals of the internal and external sounders are three increasing alarm
tones followed by a pause.
NO: The fire signals of the internal and external sounders are two seconds of continuous
tone followed by two seconds’ pause.
11
22
1313
Code Grand Master NO
YES/NO
Y
ES: Only a user with Grand Master authority can change user PINs and the time
and date.
NO: Users at the Master and Manager level can also change user PINs and the
time and date.