ABUS WIRELESS ALARM SYSTEM
INSTALLATION INSTRUCTION
These installation instructions are an important product accessory. They contain important installation and operation
information. Bear this in mind if you pass the product on to others.
Store these installation instructions in a safe place for future reference.
For a list of contents with page numbers, see page 3.
For brief instructions of starting up the ABUS wireless alarm package, see page 10-86.
Vista de página 0
1 2 3 4 5 6 ... 95 96

Resumo do Conteúdo

Página 1 - INSTALLATION INSTRUCTION

ABUS WIRELESS ALARM SYSTEM INSTALLATION INSTRUCTION These installation instructions are an imp

Página 2 - 5INWSAIMABEN-C

3-10 3.5 How can the ABUS wireless alarm system be extended? The ABUS wireless alarm system is a modular, extendable security system. The following gr

Página 3 - Contents

3-11 3.6 CE manufacturer’s declaration EG – KONFORMITÄTSERKLÄRUNG EC – DECLARATION OF CONFIRMITY Wir / We Security-Cen

Página 4

4-12 Chapter 4 Initial considerations Before starting to install your new ABUS wireless alarm system, please take the time to consider the following.

Página 5

4-13 4.1 What kinds of security are there? In general, there are three different ways of securing an object: External perimeter surveillance, in whi

Página 6 - Chapter 2 Safety information

4-14 4.3 Where do I install the ABUS wireless alarm system? The ABUS wireless alarm system should be installed in your house near an analogue telephon

Página 7

5-15 Chapter 5 Installing the ABUS wireless alarm system Make a sketch of the object or use the architect’s plans. Enter the absolutely necessary wir

Página 8

5-16 5.2 How do I install the ABUS wireless alarm system? The ABUS wireless alarm system is mounted on the wall in three steps. You need a flat screwd

Página 9

5-17 5.2.3 Fixing the faceplate Before fixing the faceplate, first read the following sections (up to page 5-20) and then return here. The preceding

Página 10

5-18 5.5 How do I connect the other contacts in the ABUS wireless alarm system? 5.5.1 Connecting a wired sounder The ABUS wireless alarm system is fit

Página 11

5-19 NOTE: 1. You can connect external equipment to clamp N.O instead of to clamp N.C. If you connect to clamp NC (normally closed), the circuit

Página 12

ABUS WIRELESS ALARM SYSTEM These installation instructions are published by ABUS Security-Center GmbH & Co. KG, Linker Kreuthweg 5, D-86444 Affin

Página 13

5-20 5.6 How are the standby batteries used? The ABUS alarm system is equipped with 6 standby batteries that maintain operation during a power failure

Página 14

5-21 5.7 What are the effects of the different jumper settings? The PC board of the ABUS wireless alarm system is fitted with internal jumpers. Confi

Página 15

6-22 Chapter 6 Programming the ABUS wireless alarm system There are several ways of programming your ABUS wireless alarm system: • At the alarm syste

Página 16

7-23 Chapter 7 Settings in installer menu This chapter describes the options and features of the installer menu of your ABUS wireless alarm system. T

Página 17

7-24 7.2 11 System Under System, you make settings that affect the entire system. This is an overview of the menu options according to their sequence

Página 18

7-25 Timers: Quick-Key Parameter Default Range 11 11 22 Exit/Entry delay 2 Exit and entry delay times of Group 2. Make these settings as for Group

Página 19

7-26 System Control: Quick-Key Parameter Default Range 11 22 0101 Quick arm YES YES/NO YES: No user PIN is necessary for activating the system o

Página 20 - CAUTION:

7-27 System Control: Quick-Key Parameter Default Range 11 22 1111 Buzzer  Bell NO YES/NO YES: If the system is activated internally and an

Página 21

7-28 System Control: Quick-Key Parameter Default Range 11 22 2020 Pager NO YES/NO Enables alphanumeric output of system events on a pager. The n

Página 22

7-29 System Control: Quick-Key Parameter Default Range 11 22 2929 Global Follower NO YES/NO YES: Specifies that all zones (that are programme

Página 23 - 00 11 33 33

Contents Chapter 1 Usage in accordance with regulations ...

Página 24

7-30 7.2.3 11 33 Receiver Under Receiver, you can make settings that control the radio receiver of your ABUS wireless alarm system. To access the Rec

Página 25

7-31 Receiver: Quick-Key Parameter Default Range 11 33 44 Delete detectors Deletes all trained wireless detectors simultaneously. To delete the wi

Página 26

7-32 7.2.5 11 55 Labels Under System Label, you name the system and areas 1, 2 and 3, and change default names. To enter a new name: Use the buttons

Página 27

7-33 System Label: Quick-Key Menu option Default Selection 11 55 22 to 11 55 44 Partitions 1 – 3 Partitions 1–3 Any 12 characters Changes the dis

Página 28

7-34 Tamper Sound: Quick-Key Parameter Default Range 11 66 22 Speaker Volume Adjusts the volume of the integrated sounder in the event of an alarm

Página 29

7-35 7.2.9 11 99 Version The Version menu shows the current version of the alarm system. To access the Version menu: 1. Select the main menu System

Página 30

7-36 7.3 22 Zones The Zones menu enables you to train wireless detectors for the system, program zone types, and define zone dependencies. This is an

Página 31

7-37 22 11 ZZZZ 44 Supervision Select whether a zone is to be monitored for regular reporting by the detectors to the alarm system. Set the monitor

Página 32

7-38 Parameter Quick-Key Parameter Default Range Zone termination A wired zone is monitored using a weak electric current. The electric current is d

Página 33 - for partition 1

7-39 Parameter Quick-Key Parameter Default Range 22 22 33 Zone Partition Partitions 1–3 Under Partition, you assign zones to different areas. Th

Página 34

7.5.2 22 Partition ...

Página 35

7-40 Parameter Quick-Key Parameter Default Range 22 22 44 ZZZZ + 0101 Exit/Entry 1 Armed/internal A zone programmed as Exit/Entry 1 must not b

Página 36

7-41 Parameter Quick-Key Parameter Default Range 22 22 44 ZZZZ + 0909 I+Entry follow (Interior+Entry Follower) Armed The I+Entry follow zone

Página 37

7-42 Parameter Quick-Key Parameter Default Range 22 22 44 ZZZZ + 1818 Exit Termination A zone with the Exit Termination zone type behaves li

Página 38

7-43 Zone sound Quick-Key Parameters Default Range 22 22 55 ZZZZ + 11 Silent No audible alarm is generated. An alarm is transmitted by telephone

Página 39

7-44 7.3.3 22 33 Zone Testing Under Testing, you can check the correct functioning of zones. To access the Testing menu: 1. Select the Zones menu as

Página 40

7-45 7.3.4 22 44 Editing Under Editing, you can copy and delete programmed zones. To access the Editing menu: 1. Select the Zones menu as described

Página 41

7-46 Editing Quick-Key Parameter 22 44 44 Delete a partition Deletes a selected partition. All zones assigned to this partition are also deleted. 1.

Página 42

7-47 7. After programming the type of interdependency, press to um define the time interval between 1 and 9 minutes. The menu for programming the

Página 43

7-48 7.4 33 Outputs Under Outputs, you program the relay and transistor outputs of the system. You link different system events to the activation of t

Página 44

7-49 Define Quick-Key Parameter 33 11 UOUO11 0404 Trouble Follow The switch output is activated if a system fault is detected. It is deactivated as s

Página 45

1-5 Chapter 1 Usage in accordance with regulations The ABUS wireless alarm system is used for protecting flats and homes and small to medium business

Página 46

7-50 Define Quick-Key Parameter 33 11 UOUO22 0808 Duress Follow The switch output is activated if a forced alarm is triggered on the operating panel i

Página 47

7-51 33 11 UOUO33 Follow Zone This menu option lists events for a zone. 33 11 UOUO33 11 Zone Follow The switch output is activated if the selected

Página 48

7-52 Output mode An output mode has to be set for every output. This table gives an overview of the different output modes: Outputs Quick-Key Paramet

Página 49

7-53 Activation/Deactivation If the switch output follows more than one area or zone, you can use different patterns for activating and deactivating

Página 50

7-54 7.5 44 Codes Under Codes, you can define user and installer Codes, define authorities, and assign areas. The ABUS wireless alarm system also has

Página 51

7-55 Authority Levels The Authority Levels menu option contains settings for the following authorities: Grand Master: There is only one Grand Maste

Página 52

7-56 7.5.2 44 22 Partition Default: Partition 1 Under Partition, you assign to user PINs partitions for which you have authority. The Grand Master is

Página 53

7-57 7.5.4 44 44 Installer Default: 0133 With the installer PIN, you have access to the installer menu and thus the authority to change all system pa

Página 54

7-58 7.5.6 44 66 Code Length Default: four digits Under Code Length, you can change the number of digits used (4 or 6) for the Grand Master, the Manag

Página 55

7-59 7.6 55 Dialer The Dialer menu enables you to transmit alarms as voice text by telephone. In this menu, you also make the settings necessary for

Página 56

2-6 Chapter 2 Safety information For damage caused by non-compliance with these installation instructions, no guarantee claims are possible. No liabil

Página 57

7-60 Access Code and ID Quick-Key Parameter Default 55 55 11 Access code 5678 Defines an access code for remote programming. The four-digit access

Página 58

7-61 Controls Quick-Key Menu option Default 55 66 0202 FM Enable NO YES: Enables FM (= Follow Me) transmission. (See also Follow Me, page 7-64.)

Página 59

7-62 Controls Quick-Key Menu option Default 55 66 1010 Answering Machine Override YES YES: Answering machine override is activated. • The upload/

Página 60

7-63 Dialer: Parameter Quick-Key Parameter Default Range 55 77 44 22 Wait 9 seconds Press 22 followed by . 55 77 55 Redial wait 30 seconds 30 or

Página 61

7-64 Dialer: Parameter Quick-Key Parameter Default Range 55 77 99 22 UD Test Hr:00 Min:00 00-24 hours 00-59 minutes Under this option, enter the fo

Página 62 - • Press to exit the menu

7-65 7.6.5 55 99 Follow Me (FM) Under this menu option, you define the forwarding of an alarm as a voice text to a telephone or a security service. I

Página 63

7-66 Follow-Me Quick-Key Parameter Default 55 99 22 Events restore Defines whether a new call is made if the event (from section 5.9.1) is reset.

Página 64 - on BTO (bell time out)

7-67 7.7 77 Key-fobs Under key-fobs, you learn how to train up to eight 4-button key-fobs with rolling code to work with the ABUS wireless alarm syst

Página 65

7-68 7.7.2 77 22 Parameters Under Parameters, you program the function and the keys of the remote control. The four buttons of the remote control can

Página 66

7-69 If you select the switch output function and confirm it with , you see the following on the display: Select a utility output with or and co

Página 67

3-7 Chapter 3 Introduction to the ABUS wireless alarm system Congratulations – you made the right choice! The ABUS wireless alarm system offers you p

Página 68

7-70 7.8 88 Keypads Under Keypads, you can assign two operating panels to the ABUS wireless alarm system. The following is an overview of the menu opt

Página 69

7-71 7.8.2 88 22 Communication Test Under Communication Test you test the radio communication between your wireless operating panel and the system. T

Página 70

7-72 7.9 99 Siren Under Siren, you can assign 3 sounders to the ABUS wireless alarm system. You can choose between internal wireless sounders and exte

Página 71

7-73 7. Confirm the Write menu option with and your alarm system waits for a signal from your sounder. Send a message from the sounder. 8. Inser

Página 72

7-74 7.9.3 99 33 Communication test Under communication test you test the radio communication between your sounder and the system. To access the commu

Página 73

7-75 7.9.5 99 55 Tamper Mute Under Tamper Mute, you can deactivate the tamper function of the sounder for the current programming process. This enabl

Página 74

7-76 7.10 00 Exit Programming Under Exit Programming, all your settings in the installer menu are saved and you exit the installer menu. Important: T

Página 75

8-77 Chapter 8 Programming within the user programming menu This chapter explains an important menu option in the user menu. This menu option is for

Página 76

8-78 8.1.1 77 11 Message structure Under Message structure, you define the sequence in which the voice messages are transmitted. To define a message

Página 77

8-79 Voice message: message name Quick-Key Parameter Default Range Recording stops automatically after 10 seconds. If you want to stop recordi

Página 78

3-8 3.2 What is the ABUS wireless alarm system? The ABUS wireless alarm system is an alarm system specially designed and developed for house owners an

Página 79

8-80 Message Labels Quick-Key Parameter Default Range 77 22 33 Partition Message Press 33. You see the following on the display: Press or t

Página 80

8-81 Message Labels Quick-Key Parameter Default Range 77 22 55 Macro Message Press 55. You see the following on the display: Press or to

Página 81

8-82 Voice message: Message test Quick-Key Parameter Default Range 77 33 11 Send message Under this menu option, you can transmit a test message

Página 82

8-83 8.1.4 77 44 Local Announcement Messages Under this menu option, you adapt local voice announcements to your requirements. To activate/deactivat

Página 83

8-84 8.2 Walk test Under the Walk test menu option, you can test your installation. When the system is in walk-test mode, you can trigger detectors wi

Página 84

9-85 Chapter 9 Accessories for your ABUS wireless alarm system The following is a list of accessories for your ABUS wireless alarm system. Wireless

Página 85

10-86 Chapter 10 Brief guide This chapter explains the installation steps shown on the DVD for the ABUS wireless alarm package including a smoke detec

Página 86 - Chapter 10 Brief guide

10-87 10.2 Training the detectors for the ABUS wireless alarm system 10.2.1 Installer menu of the ABUS wireless alarm system • First press the star

Página 87

10-88 10.2.3 Programming zones You do not have to program the zones for the detectors in your package. They are already programmed for you as follows:

Página 88

10-89 10.4 Exiting the installer menu All wireless components in the package are now trained. Your ABUS wireless alarm system is almost ready for ope

Página 89

3-9 The following graphic gives you an overview of further function properties of your ABUS wireless alarm system:

Página 90

10-90 • Confirm the menu option phone number 1 with the Enter button. • On the system keypad, enter the number with local area code and if necess

Página 91

11-91 Chapter 11 Example of an installation plan The following table provides an overview of the information your installation plan should contain:

Página 92

11-92 Partition Zone number Detector Zone type Name 1 2 3 4 5 6 7 8 9 10 11 12 13 1

Página 93

11-93 Appendix A: Event Log Messages This appendix provides descriptions of all the Event Log messages(ver 1.2xx) EVENT MESSAGE DESCRIPTION Activat

Página 94

11-94 EVENT MESSAGE DESCRIPTION Forced P=X Partition X is force armed Found Z=XXX Wireless zone found, zone No. XXX Func=XX C=YY Quick key function

Página 95

11-95 EVENT MESSAGE DESCRIPTION Spec. main KP Special alarm from the WisDom emergency keys Soak fail Z=XXX Zone XXX has failed in the Soak test