Abus FUBW50020 Manual do Utilizador Página 32

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 110
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 31
32
Note on the perimeter warning (Secvest 2WAY)
Use the “perimeter warning” as the zone type for more details refer to the instructions for
the “Secvest 2WAY” alarm panel.
Configuration
You can set several configurations on the detector see the programming table. The
default settings are shaded. Changes can be easily made. To restore the default settings,
switch off the power supply to the detector; then hold down the program button [Fig. 9] and
connect the power supply again (insert battery).
Programming table
Options
1
Range in m
10
20
30
2
Pulse counter*
1
2
*PULSE COUNTER
Number of events which both sensors must detect before an output occurs.
Vista de página 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 109 110

Comentários a estes Manuais

Sem comentários